| Step 1: Initiate Programming Mode |
| |
 |
 |
| |
| Press PROG. PGM will appear on the display. |
| |
| Step 2: Enter Trunk Mode |
| |
 |
 |
| |
| Press TRUNK. TRUNK will appear on the display and one or more bank numbers (0-10) flash. |
| |
| Step 3: Select a Bank |
| |
 |
 |
| |
| Press the number key (1-10) of the desired target storage bank. Select one of the following trunk system types by repeatedly pressing the UP or DOWN arrow keys. An E (EDACS) or M (Motorola) will also appear on the display depending on the trunk system selected.
| You See |
Trunk System |
| E1 |
Motorola Type I, 1000 MHz frequencies |
| Ed |
EDACS frequencies |
| E2-1000 |
Motorola Type II, 1000 MHz frequencies |
| E2-900 |
Motorola Type II, 900 MHz frequencies |
| E2-Hi |
Motorola Type II, VHF frequencies |
| E2-UHF |
Motorola Type II, UHF frequencies |
|
| |
| Step 4: Store the System Type |
| |
 |
 |
| |
| Press E (SVC). The scanner automatically selects the first channel in the selected bank. |
| |
| Step 5: Select a Frequency within the Trunk System |
| |
 |
 |
| |
| Use the number keys (0-9) to enter a valid frequency within the trunk system. |
| |
| Click here for Police Call Frequencies
|
| Step 6: Store the Frequency within the Trunk System |
| |
 |
 |
| |
| Press E (SVC). Bank A and the bank number (1), the channel number, and E (EDACS) or M (Motorola) appears depending upon the trunk system selected.
Notes:
- If you enter an invalid frequency (outside the selected range), the scanner beeps, the channel number flashes and ERROR appears. If this happens, press MON/CLR (.) to clear the frequency, then repeat the entry.
- For EDACS systems, you must enter the frequencies in logical channel number (LCN) order.
- If you try to enter a duplicate frequency in a bank, the scanner beeps and the channel which was previously stored appears.
- It is very important that you enter all the listed frequencies for the selected agency in Step 3. Otherwise, trunking will not occur when you press E (SRC).
|
| |
| Step 7: Store Additional Frequencies |
| |
 |
 |
| |
| Press PROG or the UP arrow key to select the next channel in the bank. Repeat from Step 5 until you enter all the desired frequencies in that bank. |
| |
| Step 8: Activate Trunk Scan and Search |
| |
 |
 |
| |
| Press SRC to begin searching for the trunk's data channel (the channel that controls the trunk). SEARCH flashes in the lower right corner as the scanner searches for the data channel. Note: As the scanner looks through the frequencies, you will see them on the display. You must have a data channel stored in your trunk channels or the scanner will not trunk. After it finds the data frequency, it will trunk between talk groups. |
| |