ET-440
(430-0564) Specifications Faxback Doc. # 8028
General
Standard Voltage
Handset.................................................. DC 3.6V +/-0.025V
Base Unit.................................. AC 120V +/-3V (with AC adapter)
Temperature........................................ 77 F +/-9F (25 C +/-5C)
Channel CH Handset (TX Frequency) Base (TX Frequency)
F 49.670 MHz 46.610 MHz
I 49.770 MHz 46.710 MHz
M 49.930 MHz 46.870 MHz
N 49.990 MHz 46.930 MHz
O 49.970 MHz 46.970 MHz
Standard Modulation................................... 1 kHz, +/-3 kHz Dev.
Secure Code................................................ Full Auto "256"
Method of Measurement................... According to EIA Standard, RS-316A
BASE UNIT
Receiver
Sensitivity at 12 dB SINAD...................................... 0.7-1.5 uV
Bandwidth at 6 dB down................................... +/-7.5 - +/-5 kHz
Frequency Response............................... +4.5 - -7.5 dB at 0.3 kHz
+4.5 - -7.5 dB at 3.0 kHz
Distortion at 1 mV RF input..................................... 2.0 - 6.0%
Frequency Tolerance.................................... +/-200 - +/-1000 Hz
S/N Ratio at 1 mV RF input........................................ 70-50 dB
Transmitter
RF Carrier Field Strength.......................................... *1 uV/m
(*1: Follow the Requirement of FCC Part 15.232 paragraph C)
Modulation Sensitivity
(Telephone Line Input -9dBm).......................... +/-2 - +/-4 kHz Dev.
Frequency Response................................... +2 - -4 dB at 0.3 kHz
0 - -6 dB at 3.0 kHz
Frequency Tolerance.................................... +/-200 - +/-1000 Hz
Telephone Line Terminal
Off-hook impedance (at 1 kHz)................................. 230-1570 ohm
Off-hook DC resistance......................................... 200-300 ohm
Telephone Line Output Voltage
at Mod. 1 kHz +/-3 kHz Dev..................................... -2 - +4 dBm
Minimum Ringer Input Level (at 20 Hz)............................. 20 - 40V
Pulse Dialing
Dialing Rate...................................................... 8-11 pps
Make Ratio.......................................................... 36-42%
DTMF Dial Frequency
Row 1....................................................... 697 +/-1.5% Hz
Row 2....................................................... 770 +/-1.5% Hz
Row 3....................................................... 852 +/-1/5% Hz
Row 4....................................................... 941 +/-1.5% Hz
Column 1................................................... 1209 +/-1.5% Hz
Column 2................................................... 1336 +/-1.5% Hz
Column 3................................................... 1477 +/-1.5% Hz
Minimum Level on Single Tone
Low Group..................................................... -6 - -10 dBm
High Group..................................................... -5 - -8 dBm
Maximum Level on Frequency Pair.............................. -2.5 - +2 dBm
HANDSET
Receiver
Sensitivity at 12 dB SINAD.................................... 0.5 - 1.5 uV
Bandwidth at 6 dB down..................................... +/-8 - +/-6 kHz
Frequency Response................................... +7 - -5 dB at 0.3 kHz
0 - -12 dB at 3.0 kHz
Audio Output Power at 1 mV Input...............................200 - 135 mV
Distortion at 1 mV input........................................ 2.0 - 6.0%
Frequency Tolerance.................................... +/-200 - +/-1000 Hz
S/N Ratio at 1 mV RF input...................................... 70 - 50 dB
Leakage ring level at ear piece............................. 80 - 120 dBSPL
Ringer Level (at 30 cm from the ringer)...................... 87 - 80 dBSPL
Transmitter
RF Carrier Field Strength.......................................... *1 uV/m
Modulation Sensitivity
(at MIC INPUT 43 mV).................................. +/-2 - +/-4 kHz Dev.
Frequency Response................................... -3 - -9 dB at 0.3 kHz
+2 - -4 dB at 3.0 kHz
Frequency Tolerance.................................... +/-200 - +/-1000 Hz
CURRENT DRAIN
Base Unit (at Line on).............................................. 4-9 VA
Handset Standby............................................... 13.5 - 18 mA
In Use 35-40 mA
Feature
Battery Low Light............................... Turns on level 3.2 to 3.5V
Battery.......................................... 270 mAH (1.2V x 3 = 3.6V)
Mode Switch................................. DTMF-Pulse (10 pps) Selectable
Power Switch............................... Power ON/OFF switch for handset
Page Switch................................................ Base to handset
Privacy............................................ Mute switch for handset
REQUIREMENTS COMPLIANCE
Unit is designed to fully meet with UL-1459 and FCC Rules, Part 15 and 68.
Note: Nominal specs represent the design specs. All units should be able
to approximate these - some will exceed and some may drop slightly
below these specs. Limit specs represent the absolute worst
condition that still might be considered acceptable; in no case
should a unit fail to meet Limit specs.
(km-03/26/1997)