Meridian 9417 Telephone
(430-5704) Page Connections Faxback Doc. # 46302
Connecting the page lines (See Faxback Doc. # 46580, Fig. 3)
The page lines must be connected in parallel with each other on pins 1
and 6 of jack 2.
For internal paging, the maximum number of Meridian 9417 telephones that
can be connected in parallel is four.
If you are connecting an external page amplifier, the maximum number of
Meridian 9417 telephones is three. The output impedance is 100 Ohms and
the nominal output level is an open circuit voltage of -20 dB v (-26 dB v
@ 600 Ohms.)
The total loop length between the originating telephone and the most
distant receiving telephone cannot exceed 1000 feet.
Note: A 6 conductor line cord is required to connect page lines. This
cable is not supplied with the Meridian 9417 telephone. Contact your
telephone representative or Telecom manager to have page lines
connected to your telephones.