ET-400 DUoFONE Cordless Telephone System
(430-0550)                  Specifications             Faxback Doc. # 16891

                              Base Unit          Handset Unit
Transmit Frequency [MHz]     46.6 to 46.9        49.6 to 49.9 
Receive Frequency [MHz]      49.6 to 49.9        46.6 to 46.9
Transmit RF Output [V]      2.5 (at 50Ohms)     2.5 (at 50Ohms)

Memory Capacity (Pulse or Tone):  28 digits
Redial Memory Capacity:           32 digits
Memory Position Capacity:         16 stations

Power Requirements
  Base Unit:      120 volts, 60Hz AC (240 volts, 50Hz for UK models
                  available only in UK)
  Handset Unit:   Rechargeable Nickel-Cadmium batteries DC 4.8V
                  (1.2V x 4)

Telephone Connections:  Use modular connectors (USOC type RJ-11C or
                        RJ-11W)

MEASUREMENT CONDITIONS

Standard Voltage
  Handset:               DC 4.8V +/- 0.1V
  Base:                  AC 120V +/- 1V, 60Hz (or 240V +/- 2V, 50Hz 
                         for UK models)
Room Temperature:        25 +/- 3 degrees C
Standard Modulation:     1kHz, 2kHz Dev.
Carrier Frequency:
  Base Unit
    TX              RX              TX              RX 
    F. 46.610 MHz   49.670 MHz      K. 46.770 MHz   49.830 MHz
    G. 46.630 MHz   49.845 MHz      L. 46.830 MHz   49.890 MHz
    H. 46.670 MHz   49.860 MHz      M. 46.870 MHz   49.930 MHz
    I. 46.710 MHz   49.770 MHz      N. 46.930 MHz   49.990 MHz
    J. 46.730 MHz   49.875 MHz      O. 46.970 MHz   49.970 MHz

PULSE DIALING

                         UNIT     NOMINAL    LIMIT
Dialing Rate             P.P.S.   10         8.0 - 11
Dialing Rate             ms       100        90 - 110
Break Ratio              %        61         58 - 64
Make Ratio               %        39         n/a
Pre-Digital Pause        ms       1000       500 - 2000
Inter-Digital Pause      ms       850        600 - 2000
Manual Access Pause      sec.     3.8        3.5 - 4.2
Flash                    sec.     0.65       0.3 - 1.0

TONE DIALING

                         UNIT     NOMINAL    LIMIT
Row 1 \                  Hz       697        687 - 707
Row 2 | Low Group        Hz       770        759 - 781
Row 3 |                  Hz       852        840 - 864
Row 4 /                  Hz       941        927 - 955
Column 1 \               Hz       1209       1191 - 1227
Column 2 | High Group    Hz       1336       1316 - 1356
Column 3 /               Hz       1477       1455 - 1499

SIGNAL LEVEL

                                      UNIT     NOMINAL    LIMIT
Minimum Level on Single Tone
  Loop Current at 20mA       
    Low Group                         dBm      -5.0       -7.5
    High Group                        dBm      -3.5       -5.5
  Loop Current at 80mA
    Low Group                         dBm      -5.0       -12
    High Group                        dBm      -3.0       -10
Maximum Level on Pair Frequency
  Loop Current at 40mA                dBm      -3.0       0
Tone Dial Single THD on Single Tone
  Loop Current (both 20mA and 50mA)   %        2.0        8.0
Duration of Signals                   ms       60         50 (min.)
Inter-Digital Time                    ms       60         50 (min.)

HANDSET UNIT

Receiver

                                 UNIT     NOMINAL    LIMIT
Sensitivity at 20dB S+N/N        uV       1.0        2.0
Squelch Sensitivity              uV       0.5        1.0
Bandwidth at -6dB                kHz      +/- 8.0    +/- 7.0
Adjacent Channel Selectivity
  at +/- 20kHz                   dB       50         35
Spurious Rejection Ration        dB       50         35
Frequency Response
     at 300Hz                    dB       +3.5       +3.5 +/- 6.0
     at 3000Hz                   dB       +14.0      +14.0 +/- 6.0
Audio Output Power               mV       30         16
THD at 1000uV RF Input           %        5.0        10
S+N/N at 1000Hz RF Input         dB       50         40
Local OSC Frequency Tolerance    Hz       +/- 500    +/- 1000
Ringer & Call Output Voltage     Vp-p     15         10

Transmitter

                               UNIT   NOMINAL       LIMIT
RF Output Voltage at 50Ohm     Vp-p   0.7           0.55
                                      0.3 (Canada)  0.15 (Canada)
Frequency Tolerance            Hz     +/- 500       +/- 1000
Frequency Response
     at 300Hz                  dB     -3.0          -3.0 +/- 6.0
     at 3000Hz                 dB     -1.5          -1.5 +/- 6.0
Modulation Sensitivity at      
  2kHz Dev.                    mV     18            9 - 36
Modulation THD                 %      5.0           10

Current Drain
                                 UNIT     NOMINAL   LIMIT
Stand-by                         mA       15        20
Talk                             mA       45        68
Battery Low LED Turn-on Voltage  V        4.75      4.75 +/- 0.15

BASE UNIT

Receiver
                                 UNIT     NOMINAL   LIMIT
Sensitivity at 20dB S+N/N        uV       2.0       4.0
Squelch Sensitivity              uV       0.5       1.0
Bandwidth at -6dB                kHz      +/- 8.0   +/- 7.0
Adjacent Channel Selectivity
  at +/- 15kHz                   dB       40        27
Spurious Rejection Ratio         dB       50        35
Frequency Response
     at 300Hz                    dB       -5.0      -5.0 +/- 6.0
     at 3000Hz                   dB       -3.0      -3.0 +/- 3.0
Telephone Line Output Level      dBm      -2.0      -2.0 +/- 3.0
THD at 1000uV RF Input           %        5.0       10
S+N/N at 1000uV RF Input         dB       50        40
Local OSC Frequency Tolerance    Hz       +/- 500   +/- 1000

NOTE:  Nominal specs represent the design specs; all units should be able
       to approximate these--some will exceed and some may drop slightly
       below these specs.  Limit specs represent the absolute worst
       condition that still might be considered acceptable; in no case
       should a unit perform to less than within any limit spec.

Transmitter

                                 UNIT     NOMINAL       LIMIT
RF Output Volatge at 50Ohm       Vp-p     0.25          0.18
                                          0.7 (Canada)  0.55 (Canada)
Frequency Tolerance              Hz       +/- 500       +/- 1000
Frequency Response
     at 300Hz                    dB       -9.0          -9.0 +/- 6.0
     at 3000Hz                   dB       8.0           8.0 +/- 6.0
Modulation Sensitivity at
  2kHz Dev.                      dBm      -10           -10 +/- 3.0
Modulation THD                   %        5.0           10
AC Power Consumption             VA       3.5           7.0
Minimum Ringer Input Voltage     V        35            40
EIA Ringer Tap Voltage           V        130           105
Minimum Ringer Input Voltage

Privacy Policy