Indoor/Outdoor Thermometer
(630-1026) Specifications Faxback Doc. # 50954
Power (Main Unit): .............................. 3V with Two AA Batteries
(Remote Sensor): .......................... 3V with Two AA Batteries
Note: At temperatures below -4 degrees F (-20 degrees C), use
lithium batteries (Cat.No. 23-664) in the remote sensor
Range:
(Main Unit): .................. 23 to 122 degrees F (-5 to 50 degrees C)
(Remote Sensor):
(using alkaline batteries): -4 to 140 degrees F (-20 to 60 degrees C)
(using lithium batteries): -50 to 140 degrees F (-45 to 60 degrees C)
Resolution: ................................ 0.2 degrees F (0.1 degrees C)
Sampling Cycle (Approximate)(Main Unit): ...................... 10 Seconds
(Remote Sensor): .................. 30 Seconds
Accuracy:
(Main Unit): .... +/- 4 degrees at 23 to 32 degrees F (-5 to 0 degrees C)
+/- 2 degrees at 32 to 104 degrees F (0 to 40 degrees C)
+/- 4 degrees at 104 to 122 degrees F (40 to 50 degrees C)
(Remote Sensor): +/- 4 degrees at -4 to 32 degrees F (-20 to 0 degrees C)
+/- 2 degrees at 32 to 104 degrees F (0 to 40 degrees C)
+/- 4 degrees at 104 to 122 degrees F (40 to 50 degrees C)
+/- 6 degrees at 122 to 140 degrees F (50 to 60 degrees C)
Weight (without batteries)(Main Unit): .................... 5.7 oz (162 g)
(Remote Sensor): ................ 3.5 oz (100 g)
Dimensions:
(Main Unit): ........... 4-5/8 x 4-3/16 x 1 Inches (117 x 107 x 26 mm)
(Remote Sensor): .. 4-1/16 x 2-11/16 x 13/16 Inches (103 x 68 x 21 mm)
Specifications are typical; individual units might vary. Specifications
are subject to change and improvement without notice.
(EB 12/28/98)
Privacy Policy