DX-395 FM/AM/SW1/SW2 PLL Synthesized Receiver
(200-0225)                 Specifications             Faxback Doc. # 18587

General Specifications:

Frequencies:

   AM: ........................................ 530-1710 kHz @ 10 kHz Steps

   FM: ..................................... 87.5-107.9 MHz @ 200 kHz Steps

   SW1: ......................................... 3.2-7.3 MHz @ 5 kHz Steps

   SW2: ....................................... 9.5-21.75 MHz @ 5 kHz Steps

Power Sources: ............ 2 AAA batteries (for backup) (Cat. No. 23-555),
                                      and 4 AA batteries (Cat. No. 23-552),
                                             AC Adapter (Cat. No. 273-1650)
                                               DC Adapter (Cat. No. 14-844)

Battery Life Expectancy:

    NiCad: ................ 3 Hours @ Max. Volume / 11 Hours at Min. Volume
    Alkaline: .................................. 30 - 40 Hours @ Low Volume

NOTE: Above hours of life expectancy are approximate. The actual times will
      vary depending on the type of use or combinations of use.

Dimensions (HWD): .......................... 4-3/8 x 7-5/8 x 1-11/16 Inches
                                                        (111 x 193 x 42 mm)

Weight: .............................................. 1 lb. 7 oz. (771 gm)

AM Band Specifications:

Standard Modulation: .......................................... 400 Hz, 30%

Intermediate Frequency: ................................. 450 kHz +/- 5 kHz

Frequency Range: ................................. 530 - 1710 kHz +/- 5 kHz

Maximum Sensitivity @ 600 kHz: ................................... 501 uV/m
                   @ 1000 kHz: ................................... 501 uV/m
                   @ 1400 kHz: ....................................501 uV/m

20 dB S/N Sensitivity @ 600 kHz: ................................ 1000 uV/m
                     @ 1000 kHz: ................................ 1000 uV/m
                     @ 1400 kHz: ................................ 1000 uV/m

AM Scan Sensitivity @ 600 kHz: .................................. 1000 uV/m
                   @ 1000 kHz: .................................. 1000 uV/m
                   @ 1400 kHz: .................................. 1000 uV/m

S/N Ratio, (5 mV/m Input) @ 1000 kHz: ............................... 30 dB

Image Rejection @ 1400 kHz: ......................................... 35 dB

IF Rejection @ 600 kHz: ............................................. 40 dB

AGC-10 dB, (100 mV/m Input) @ 1000 kHz: ............................. 45 dB

Bandwidth -6 dB @ 1000 kHz: ...................................... < 10 kHz

Selectivity +/- 10 kHz @ 1000 kHz: .................................. 30 dB

Maximum Output Power, (5 mV/m Input) @ 1000 kHz: ................... 400 mW

10% THE Output Power, (5 mV/m Input) @ 1000 kHz: ................... 320 mW

Distortion, (5 mV/m Input) @ 1000 kHz: ................................. 2%

Overload Distortion 80% Modulation, (100 mV/m Input) @ 1000 kHz: ....... 5%

Whistle Modulation, (50 mV/m Input) @ 2 x IF: .......................... 4%
                                    @ 3 x IF: .......................... 3%

Audio fidelity -6 dB, (5 mV/m Input) @ 1000 kHz: ............ 100 - 2000 Hz

Noise Level at Volume Minimum @ 1000 kHz: ............................ 1 mV

Current Drain at Volume Min./Max., (5 mV/m Input) @ 1000 kHz: ... 40/180 mA

Minimum Operating Voltage, (5 mV/m Input) @ 1000 kHz: ............... 3.6 V

NOTE:  The standard output level is 50 mW at 8 Ohms  (resistive load).  The
       input level is 5 mV/m 400 Hz 30% modulation.

FM Band:

Signal generator impedance: ........................................ 75 Ohm

Disconnect the antenna wire.

The signal voltage listed in this specification  or in the test data is the
voltage appearing across the tuner input terminal.

Modulation: .................................... 400 Hz, 22.5 kHz deviation

Intermediate Frequency: .......................................... 10.7 MHz

Frequency Range: ............................. 87.5 - 107.9 MHz +/- 0.1 MHz

30 dB S/N Sensitivity @ 89.9 MHz: .................................... 8 uV
                      @ 98.1 MHz: .................................... 8 uV
                      @ 106.1 MHz: ................................... 8 uV

Auto Scan Sensitivity @ 89.9 MHz: .................................... 8 uV
                      @ 98.1 MHz: .................................... 8 uV
                      @ 106.1 MHz: ................................... 8 uV

Distortion, (1000 uV Input) @ 98.1 MHz: ................................ 1%

Overload THD, (50 mV Input) @ 98.1 MHz: ................................ 3%

Maximum Output Power, (1000 uV Input) @ 98.1 MHz: .................. 475 mW

10% THD Output Power, (1000 uV Input) @ 98.1 MHz: .................. 320 mW

S/N Ratio, (1000 uV Input) @ 98.1 MHz: .............................. 50 dB

-3 dB Limiting @ 98.1 MHz: ........................................... 8 uV

Image Rejection Ratio @ 106.1 MHz: .................................. 25 dB

IF Rejection Ratio @ 89.9 MHz: ...................................... 60 dB

Capture Ratio, (100 uV Input) @ 98.1 MHz: ............................ 4 dB

Alternate Channel Selectivity +/- 400 kHz, (100 uV Input) @ 98.1 MHz: 25 uV
                                          (1000 uV Input) @ 98.1 MHz: 25 uV

Spurious Response (+1/2 IF/206.9 MHz) @ 98.1 MHz: ................... 36 dB

De-emphasis, 100 Hz, (1000 uV Input) @ 98.1 MHz: .................... -1 dB
               6 Hz, (1000 uV Input) @ 98.1 MHz: .................... -9 dB

Noise Level at Volume Minimum @ 98.1 MHz: ............................ 1 mV

AM Suppression, (1000 uV Input) @ 98.1 MHz: ......................... 40 dB

Current Drain at Volume Min./Max., (1000 uV Input) @ 98.1 MHz: .. 55/200 mA

Minimum Operating Voltage, (1000 uV Input) @ 98.1 MHz: .............. 3.6 V

Local/DX Effect @ 98.1 MHz: ......................................... 12 dB

Clock Accuracy at 25 degrees C.: .............................. 0.5 sec/day

European model must not be able to go below 87.5 MHz.

NOTE:  With the volume control in its maximum position, connect the signal
       generator to the antenna wire input terminal (through the suitable
       impedance matching network).

The standard output level is 50 mW at 8 Ohms (resistive load).  The input
level is 1000 uV 400 Hz 22.5 kHz.

SW1 Band:

Signal generator impedance: ........................................ 75 Ohm

Disconnect the antenna wire.

Input directed to antenna end feed via a 15 pF capacitor.

The signal voltage listed in this specification or in the test data is the
voltage appearing across the tuner Input terminal.

Modulation: ................................................... 400 Hz, 30%

Intermediate Frequency: ........................................... 450 kHz

Frequency Range: ................................ 3.2 - 7.3 MHz +/- 0.1 MHz

Maximum Sensitivity @ 4 MHz: ......................................... 4 uV
                    @ 5 MHz: ......................................... 4 uV
                    @ 6.5 MHz: ....................................... 4 uV

6 dB S/N Sensitivity @ 4 MHz: ....................................... 10 uV
                     @ 5 MHz: ....................................... 10 uV
                     @ 6.5 MHz: ..................................... 10 uV

20 dB S/N Sensitivity @ 4 MHz: ...................................... 15 uV
                      @ 5 MHz: ...................................... 15 uV
                      @ 6.5 uV: ..................................... 15 uV

Auto Scan Sensitivity @ 4 MHz: ...................................... 20 uV
                      @ 5 MHz: ...................................... 20 uV
                      @ 6.5 MHz: .................................... 20 uV

S/N Ratio (1 mV Input) @ 5 MHz: ..................................... 40 dB

Image Rejection Ratio @ 6.5 MHz: .................................... 13 dB

Distortion, (1 mV Input) @ 5 MHz: ...................................... 2%

Bandwidth -6 dB @ 5 MHz: ............................................ 5 kHz

Noise Level at Volume Minimum @ 5 MHz: ............................... 1 mV

Minimum Operating Voltage, (1 mV Input) @ 5 MHz: .................... 3.6 V

Local / DX Effect @ 5 MHz: .......................................... 25 dB

NOTE:  The standard output level is 50 mW at 8 Ohms (resistive load).  The
       input level is 1 mV 400 Hz 30% modulation.

SW2 Band:

Signal generator impedance: ........................................ 75 Ohm

Disconnect the antenna wire.

Input directed to antenna end feed via a 15 pF capacitor.

The signal voltage listed in this specification or in the test data is the
voltage appearing across the tuner Input terminal.

Modulation: ................................................... 400 Hz, 30%

Intermediate Frequency: ........................................... 450 kHz

Frequency Range: .............................. 9.5 - 21.75 MHz +/- 0.1 MHz

Maximum Sensitivity @ 12 MHz: ....................................... 10 uV
                    @ 15 MHz: ....................................... 10 uV
                    @ 19 MHz: ....................................... 10 uV

20 dB S/N Sensitivity @ 12 MHz: ..................................... 15 uV
                      @ 15 MHz: ..................................... 15 uV
                      @ 19 uV: ...................................... 15 uV

Auto Scan Sensitivity @ 12 MHz: ..................................... 30 uV
                      @ 15 MHz: ..................................... 30 uV
                      @ 19 MHz: ..................................... 30 uV

S/N Ratio (1 mV Input) @ 15 MHz: .................................... 40 dB

Image Rejection Ratio @ 19 MHz: ..................................... 10 dB

Distortion, (1 mV Input) @ 15 MHz: ..................................... 2%

Noise Level at Volume Minimum @ 15 MHz: .............................. 1 mV

Minimum Operating Voltage, (1 mV Input) @ 15 MHz: ................... 3.6 V

Local / DX Effect @ 15 MHz: ......................................... 25 dB

NOTE:  The standard output level is 50 mW at 8 Ohms (resistive load).  The
       input level is 1 mV 400 Hz 30% modulation.

NOTE:  Normal specs represent the design specs. All units should be able to
       approximate these, some will exceed and some may drop slightly below
       these specs. Limit specs represent the absolute worst condition that
       might still be considered acceptable; in no case should a unit fail
       to meet limit specs.

Specifications are typical; individual units might vary. Specifications are
subject to change and improvement without notice.


(JC/EB 6/17/97) 

Privacy Policy