Cassette Replacement (330-2001) Specifications Faxback Doc. # 15323
Mike
This standard describes the requirements for a dynamic microphone type,
handheld, for use in tape recorder.
ELECTRICAL REQUIREMENTS
Impedance:.........................................500 Ohms +/- 30% at 1KHz
Directivity:...............................................Omni-Directional
Sensitivity:..........................-78 +/- 3dB at 1KHz (odB=1V/microbar)
Frequency Response:.............................................100Hz-10KHz
MECHANICAL REQUIREMENTS
Durability of Switch:..................Normal after 10,000 cycles operation
Cord Strain Relief:......................Normal after supplied 5kg force at
both end of mic or plug for 1 sec.
Drop Test:.......................Normal after free fall from 1 meter height
to concrete floor each one for 5 times
Vibration Test:...................Normal after vibrations, 12Hz to 55Hz for
1 minute full amplitude 2mm for 1.5 hours
at three axises
Temperature Cycle Test:...............After exposure at -10 degrees C for 1
hour, at 25 degrees C for 1 hour, at
55 degrees C for 1 hour, 2 cycles,
frequency response, sensitivity should
be within specifications.
Humidity Test:....................After exposure at 40 degrees C and 90-95%
RH relative humidity for 48 hours, frequency
response, sensitivity should be within
specifications
(The measurement should be done after 2
hours of conditioning at 25 degrees C)
Operating Temperature:........................-10 degrees C to 55 degrees C
(ALL-05/18/95)