FP 215 (260-1193) Interface Faxback Doc. # 5916
The Plotter is equipped with a serial interface and a parallel interface.
Either can be selected as desired by a built-in selector switch.
NOTE: When a serial interface and a parallel interface are connected at the
same time, the XY PLOTTER does not move.
Connector and Cable
(1) Connector
1) Parallel
Plotter side: 36-pole connector (female)
(57L-40360-27C)
(Manufactured by Daiichi Denshi
Kogyo or equivalent)
Cable side: 36-pole connector (male)
(57l-30360-D8)
(Manufactured by Daiichi Denshi
Kogyo or equivalent)
2) Serial
Plotter side: 4-pin DIN receptacle
(TCS +440)
(Hoshiden Co., Ltd.)
Cable side: 4-pin DIN plug
(TCP 0546-01-010)
(Hoshiden Co., Ltd.)
(2) Cable
For noise control, twisted pair cables should be used, with a maximum
length of 1m.
(jej 04/26/94)